Achieving optimal quantum acceleration of frequency estimation using adaptive coherent control

Achieving optimal quantum acceleration of frequency estimation using adaptive coherent control

M. Naghiloo Department of Physics, Washington University, St. Louis, Missouri 63130    A. N. Jordan Department of Physics and Astronomy, University of Rochester, Rochester, NY 14627 Center for Coherence and Quantum Optics, University of Rochester, Rochester, NY 14627 Institute for Quantum Studies, Chapman University, Orange, CA 92866, USA    K. W. Murch Department of Physics, Washington University, St. Louis, Missouri 63130 Institute for Materials Science and Engineering, St. Louis, Missouri 63130
August 17, 2019
Abstract

Precision measurements of frequency are critical to accurate timekeeping, and are fundamentally limited by quantum measurement uncertainties. While for time-independent quantum Hamiltonians, the uncertainty of any parameter scales at best as , where is the duration of the experiment, recent theoretical works have predicted that explicitly time-dependent Hamiltonians can yield a scaling of the uncertainty for an oscillation frequency. This quantum acceleration in precision requires coherent control, which is generally adaptive. We experimentally realize this quantum improvement in frequency sensitivity with superconducting circuits, using a single transmon qubit. With optimal control pulses, the theoretically ideal frequency precision scaling is reached for times shorter than the decoherence time. This result demonstrates a fundamental quantum advantage for frequency estimation.

The ability to sense more accurately has historically been the basis of many of our scientific advances and technological innovations. In particular, precision measurements have been instrumental in advancing our knowledge of fundamental physical laws Abe and et. al. (2008); Walker et al. (1994); Aguilar and et. al. (2013); Rosi et al. (2014). Notably, frequency measurements have been essential to experimental tests of general relativity, the standard model of particle physics, and quantum mechanics, and are the practical foundation of all timekeeping devices. The precision of measurements is ultimately governed by the fundamentally probabilistic nature of quantum measurements, which arises most basically in the Heisenberg uncertainty principle. Traditionally, frequency measurements, such as are conducted with atomic clocks Essen and Parry (1955); Lyons (1957); Ludlow et al. (2015), are associated with the measurement of the energy difference, , between two eigenvalues of a static Hamiltonian , and the frequency uncertainty arises from the energy-time uncertainty principle Gabor (1946), , where is the time of the experiment. New situations arise in frequency metrology when one considers instead time-dependent Hamiltonians, where the precision of frequency measurements can be optimized with additional control.

In metrology, one seeks to determine a parameter from repeated measurements that naturally follow a probability distribution , where is some random variable. For large data sets, the Cramér-Rao bound Cramér (1946) gives a universal limit for the mean squared deviation of the parameter,

(1)

where is a measure of the amount of data, is an unbiased estimator of the parameter formed from measurement data, and is the Fisher information Fisher (1925) which characterizes the amount of information about the parameter that is contained in the data. Therefore, the Fisher information is a natural measure of how optimal a given measurement strategy is for determining the parameter with minimal uncertainty.

For quantum parameter estimation, measurements on quantum states are used to find the probability distribution . In this case the Fisher information in the quantum state is given by Braunstein and Caves (1994); Braunstein et al. (1996),

(2)

which maximizes the classical Fisher information in the measurement results on the state over all possible types of quantum measurements. The quantum Fisher information is a measure of the distinguishability of two states and and with this formulation, it is clear that some quantum states garner more quantum Fisher information than others. In particular non-classical correlations can enhance measurement sensitivities. The use of such non-classical resources in measurement has been widely studied Alipour et al. (2014); Tsang et al. (2011); Giovannetti et al. (2004) and applied in several metrological areas including imaging Kolobov (1999), gravitational waves Collaboration (2011), and magnetometry Sewell et al. (2012). Much of this research has focused on the scaling of the quantum Fisher information with the number of quantum systems; whereas uncorrelated systems lead to the standard quantum limit , appropriate quantum correlations can lead to the Heisenberg scaling Giovannetti et al. (2004).

Figure 1: Frequency estimation of a time-periodic Hamiltonian. (a), The experiment consists of a transmon qubit dispersively coupled to a waveguide cavity. The qubit is subject to a time-dependent Hamiltonian and the task is to estimate the frequency . (b), The eigenvalues of . The quantum Fisher information is related to the integral of , which is alternately positive or negative. (c), A control is used to guide the qubit evolution such that and are maximally separated. (d), The scaling of the quantum Fisher information for the uncontrolled and controlled measurement evolution, showing scaling as and respectively.

Here, we focus rather on how the quantum Fisher information for a single quantum system scales with time Itano et al. (1993). If, for example, the parameter to be estimated is a multiplicative factor Giovannetti et al. (2006) on a static Hamiltonian, , then, given that unitary evolution for a time is described by , the quantum Fisher information scales in time as Giovannetti et al. (2006). However, if the Hamiltonian is instead time-dependent Tsang et al. (2011); de Clercq et al. (2016) the quantum Fisher information may exceed this scaling for certain parameters, reaching a scaling of for estimating the frequency of an oscillating Hamiltonian under optimal coherent control Pang and Jordan (2017). Very recent experiments Boss et al. (2017); Schmitt et al. (2017); Jordan (2017) in magnetic field sensing NV centers have demonstrated that using a hybrid quantum/classical strategy of estimating a local magnetic field value with a quantum technique, repeated in time, together with a classical Fourier transform can achieve a Fisher information of the frequency scaling as . In this letter, we experimentally demonstrate scaling of the quantum Fisher information in the estimation of a Hamiltonian oscillation frequency for a pseudo-spin half system. This quantum enhanced scaling has been proved Pang and Jordan (2017) to be the best allowed by quantum mechanics in the kind of system we consider in this work. This improved scaling is achieved through adaptive optimal control where an additional control Hamiltonian that depends on the estimated parameter is applied to the system to enhance sensitivity. We show that the scaling is robust against small variations in the control Hamiltonian, thus allowing for adaptive control.

To illustrate how optimal control can be used to maximize the quantum Fisher information, we consider a time-dependent Hamiltonian imposed on a two-level quantum system , describing periodic modulation of the energy levels of the system with amplitude as shown in Figure 1a. Our focus is to maximize the quantum Fisher information of the modulation frequency , that is to minimize the overlap of two quantum states and after time evolution under the Hamiltonian for time . We will show that the optimal choice of quantum states is a superposition of energy eigenstates , which accumulate different phases under the Hamiltonian evolution.

To formalize our discussion of the quantum Fisher information, we reformulate Equation 2 as , where , is the unitary evolution of the initial state under the Hamiltonian, and represents the variance. In this form, we can see that the quantum Fisher information is related to the squared difference between the minimum and maximum eigenvalues of .

Figure 2: Frequency metrology with optimal control. (a), Schematic of the estimation task: The qubit is prepared in a superposition of energy eigenstates , followed by an interaction with a time-periodic Hamiltonian with frequency for a certain time, followed a pulse and projection in the basis to determine the acquired phase. (b), The energy eigenvalue difference of Hamiltonian is sketched in time, together with the optimal coherent control pulses (repeated pulses at the antinodes of the oscillating Hamiltonian) designed to acquire maximum frequency information. This results in the effective total Hamiltonian, . The acquired phase is the time integral of this function. (c), The frequency sensitivity is determined by varying , and a linear fit determines . (d), The phase uncertainty versus experimental repetition number shows that the phase uncertainty is given by the binomial error (solid line). (e), The frequency sensitivity, for the uncontrolled (red circles) and optimal control (blue diamonds) attain the respective limits (solid lines) for times shorter than the decoherence time. The error bars indicate the estimated standard deviation of slope from the linear regression fit as in panel (c). (e)(Inset), The quantum Fisher information associated with a given measurement protocol (uncontrolled; red, controlled; blue), determined from the slope of the acquired phase versus frequency is displayed on a log-log plot versus time.

To determine the eigenvalues of , we break the unitary evolution into infinitesimal time intervals as discussed in Pang and Jordan (2017), and consider the eigenvalues of versus time. In the current case, the Hamiltonian commutes with itself at different times, so we arrange the system to be in a superposition of the eigenstates of , such that the eigenvalues maintain maximal separation. These eigenvalues simply evolve as . In Figure 1b we sketch . The quantum Fisher information about the frequency associated with an evolution for time is given by,

(3)

which increases as . Figure 1c displays how additional control at the crossing points can be used to dramatically enhance the QFI. By applying a control to guide the qubit along a trajectory that maximizes the integral (3), the QFI can increase instead as as shown in Figure 1d. The intuitive reason for the scaling versus the scaling is that for time-independent Hamiltonians, two nearby quantum states corresponding to different values of the parameter can only diverge from each other with constant velocity, whereas in time-dependent Hamiltonians, they can accelerate away from each other, giving greater quantum distinguishability of the states in the same period of time Pang and Jordan (2017); Yang et al. (2017); Gefen et al. (2017).

We now turn to the experiment, where we realize the optimal control depicted in Figure 1c. The experimental setup consists of a superconducting transmon circuit Koch et al. (2007) that is dispersively coupled to a waveguide cavity Paik et al. (2011). The qubit system is comprised of the lowest two levels of the circuit, and is described by the Pauli spin operators . The dispersive interaction between the qubit and the cavity, described by the Hamiltonian allows for rapid, quantum non-demolition measurement of the qubit in the energy basis by probing the cavity resonance with microwave photons. Here MHz is the dispersive coupling rate and is the cavity photon number operator. To create the time-dependent Hamiltonian, , we drive the cavity with detuning MHz to populate the cavity with an average photons. The mean photon number results in an ac Stark shift of MHz and the modulation amplitude MHz.

We first demonstrate the standard scaling of the quantum Fisher information that is obtained without Hamiltonian control. An equal superposition state maximizes the QFI, and the measurement protocol is simply a Ramsey sequence as depicted in Figure 2a. A pulse is applied, followed by waiting for a time , followed by a second pulse and projective measurement in the basis. The axis of the second rotation is adjusted such that the projective measurement in the energy basis accumulates maximal information about the phase of the qubit. The QFI is given in terms of the Bures distance Bures (1969), , where . As such, we vary by a small amount to determine the slope (Figure 2c), where . The frequency sensitivity is ultimately governed by the QFI and the phase variance, which as shown in Figure 2d is given by the standard binomial error due to projection noise, resulting in a cumulative frequency information of . As displayed in Figure 2e, the frequency sensitivity improves as , (QFI ) until dephasing of the qubit, characterized by s degrades the sensitivity.

The key idea behind optimal coherent control is to impose an additional time dependent Hamiltonian to maximize the difference of the eigenvalues of . In Figure 2b we display this optimal Hamiltonian control, which consists of discrete unitary rotations applied to the qubit at specific optimal times: these are applied at the antinodes of the estimated Hamiltonian, rather that at the nodes as is commonly seen in dynamical decoupling sequences Yang et al. (2017). In contrast to dynamical decoupling pulses, whose object is to refocus diverging states and prolong coherence, our control pulses do the opposite: the objective is to separate as quickly as possible two quantum states corresponding to nearby values of the frequency in order to improve our resolution of that parameter; hybrid schemes have very recently been proposed Gefen et al. (2017). In Figure 2e we show how under optimal control the frequency sensitivity attains the ultimate limit for short times and yields better sensitivity over the no-control case as long as . This corresponds to a scaling of the QFI. At long times, decoherence of the qubit causes the QFI to decrease due to increasing overlap of the states and .

The optimal Hamiltonian control yields a improvement over the QFI obtained with a standard Ramsey measurement. Given a finite time resource in metrology, such as the finite time of the qubit, this yields a substantial improvement in QFI, amounting to a factor of 740 in this experimental demonstration.

In contrast to recent work Boss et al. (2017); Schmitt et al. (2017) where scaling of the QFI has been observed for times only limited by the stability of an external reference, the scaling observed here is limited to times . If we consider sensing for a duration longer than , the optimal approach is to utilize repeated, back-to-back measurements each with duration . By taking advantage of the fact that these repeated measurements sample the signal at different times a scaling of the QFI for the total signal sampling time is also possible with our approach, but with an optimized prefactor.

Having demonstrated such a significant improvement in the scaling of the quantum Fisher information with time, it is worth inquiring as to whether other Hamiltonian parameters can be estimated with such precision. For example, could the QFI associated with the amplitude of the time dependent Hamiltonian also achieve such scaling, or at least an improvement under optimal control compared to the uncontrolled case? To address this, we again consider the eigenvalues of , , which do not increase in time. As is well known from work with nitrogen-vacancy spin sensing de Lange et al. (2011); Mamin et al. (2013); Loretz et al. (2014); Sushkov et al. (2014); Lovchinsky et al. (2016), in this case the optimal control strategy is again to apply rotations, but this time at nodes of the Hamiltonian, and yields an overall scaling of the quantum Fisher information as we discuss in the Supplemental Information sup . This is an improvement over the no-control case, where the maximum quantum Fisher information does not increase for longer interaction times.

We note that the optimal control needed to obtain the enhanced precision of the frequency depends on knowledge of the phase and frequency, which is itself the parameter to be estimated! Therefore, in general, we must apply adaptive control Waldherr et al. (2012); Baumgratz and Datta (2016); Yuan and Fung (2015); Yuan (2016) where first some crude knowledge of the parameter is obtained without control, which is then used in the control Hamiltonian to obtain a more precise estimate of the parameter, which is fed back to adjust the coherent control in an adaptive loop until the optimal arrangement is converged upon. One might worry that the scaling is so sensitive to the matching of the time-dependent Hamiltonian and control that the scaling is difficult to achieve in practice. The degradation of the QFI due to frequency mismatch between the control and the parameter was analyzed for the case of a rotating magnetic field in Ref. Pang and Jordan (2017) and by applying a similar analysis here, we find that the QFI in the presence of a frequency mismatch is to leading order . Because the correction grows as , an iterative procedure is required to refine the control frequency. The requirements on matching the phase of the control leads to a correction to the QFI proportional to , which only depends on the phase mismatch, and does not grow with time sup . In Figure 3 we show the experimentally obtained quantum Fisher information for different mismatches between the phase and frequency of the control Hamiltonian. As shown in Figure 3a, the QFI reaches a maximum when the control is matched to the modulation frequency with vanishing phase offset. Figure 3a also highlights how this control landscape can be mapped without knowledge of the parameters that are to be estimated.

Figure 3: Optimal control landscape. (a), Color plot of the QFI as two control parameters are swept for s: the phase difference between the control pulses the periodic Hamiltonian modulation (-axis), and the duration between the pulses (-axis) as specified by the control frequency . The phase difference has been shifted slightly to account for a 6-ns delay between the control pulses and the periodic Hamiltonian. (b,c), Line cuts through the control landscape (locations indicated as dashed red lines in (a)) show that for small parameter mismatches the QFI is still significantly greater than the uncontrolled case (red line). The blue regions show the parameter uncertainty based on uncontrolled estimation using experimental repetitions.

Figure 3b,c display the QFI versus frequency and phase mismatch in detail. For the s interaction time considered here, uncontrolled frequency and phase estimation based on experimental repetitions (used to reduce the phase uncertainty) is sufficient to find the maximum in the QFI available with optimal control. Therefore, the robustness of the optimal control improvement in QFI to variations in the control parameters is sufficient to allow adaptive control to rapidly converge to the optimal values. In fact, in Ref. Pang and Jordan (2017) it was proved that the number of iterations required to approach the maximum sensitivity grows only as a double-logarithm of the total time and in the Supplemental Information sup we discuss how an iterative procedure can be used to adaptively improve the frequency precision.

In quantum enhanced metrology, one seeks to take advantage of quantum properties to maximally utilize the available measurement resources. For parallel resources, such as the number of quantum systems, entanglement can be utilized to achieve Heisenberg scaling. We have demonstrated how quantum coherence, optimally harnessed through coherent control, can maximally utilize the serial resource: time. It is theoretically possible to combine both the serial and parallel resources which would give the best case quantum precision. The advantages conferred in frequency metrology with time-dependent Hamiltonians opens new horizons in precision measurement and time-keeping.

Acknowledgements.
Acknowledgements—We acknowledge P. M. Harrington, D. Tan, and J. T. Monroe for discussions, sample fabrication, and contributions to the experimental setup. We acknowledge research support from NSF grants DMR-1506081 and PHY-1607156, the ONR No. 12114811 and the ARO No. W911NF-15-1-0496. This research used facilities at the Institute of Materials Science and Engineering at Washington University. K.W.M acknowledges support from the Sloan Foundation.

References

  • Abe and et. al. (2008) S. Abe and et. al. (The KamLAND Collaboration), Phys. Rev. Lett. 100, 221803 (2008).
  • Walker et al. (1994) B. Walker, B. Sheehy, L. F. DiMauro, P. Agostini, K. J. Schafer, and K. C. Kulander, Phys. Rev. Lett. 73, 1227 (1994).
  • Aguilar and et. al. (2013) M. Aguilar and et. al. (AMS Collaboration), Phys. Rev. Lett. 110, 141102 (2013).
  • Rosi et al. (2014) G. Rosi, F. Sorrentino, L. Cacciapuoti, M. Prevedelli, and G. Tino, Nature 510, 518 (2014).
  • Essen and Parry (1955) L. Essen and J. Parry, Nature 176, 280 (1955).
  • Lyons (1957) H. Lyons, Scientific American 196, 71 (1957).
  • Ludlow et al. (2015) A. D. Ludlow, M. M. Boyd, J. Ye, E. Peik, and P. O. Schmidt, Rev. Mod. Phys. 87, 637 (2015).
  • Gabor (1946) D. Gabor, Journal of the Institution of Electrical Engineers-Part III: Radio and Communication Engineering 93, 429 (1946).
  • Cramér (1946) H. Cramér, Mathematical Methods of Statistics (Princeton University Press, 1946).
  • Fisher (1925) R. A. Fisher, Math. Proc. Cambridge Philos. Soc. 22, 700 (1925).
  • Braunstein and Caves (1994) S. L. Braunstein and C. M. Caves, Phys. Rev. Lett. 72, 3439 (1994).
  • Braunstein et al. (1996) S. L. Braunstein, C. M. Caves, and G. Milburn, Annals of Physics 247, 135 (1996), ISSN 0003-4916.
  • Alipour et al. (2014) S. Alipour, M. Mehboudi, and A. T. Rezakhani, Phys. Rev. Lett. 112, 120405 (2014).
  • Tsang et al. (2011) M. Tsang, H. M. Wiseman, and C. M. Caves, Phys. Rev. Lett. 106, 090401 (2011).
  • Giovannetti et al. (2004) V. Giovannetti, S. Lloyd, and L. Maccone, 306, 1330 (2004), ISSN 0036-8075.
  • Kolobov (1999) M. I. Kolobov, Rev. Mod. Phys. 71, 1539 (1999).
  • Collaboration (2011) T. L. S. Collaboration, Nature Physics 7, 962 (2011).
  • Sewell et al. (2012) R. J. Sewell, M. Koschorreck, M. Napolitano, B. Dubost, N. Behbood, and M. W. Mitchell, Phys. Rev. Lett. 109, 253605 (2012).
  • Itano et al. (1993) W. M. Itano, J. C. Bergquist, J. J. Bollinger, J. M. Gilligan, D. J. Heinzen, F. L. Moore, M. G. Raizen, and D. J. Wineland, Phys. Rev. A 47, 3554 (1993).
  • Giovannetti et al. (2006) V. Giovannetti, S. Lloyd, and L. Maccone, Phys. Rev. Lett. 96, 010401 (2006).
  • de Clercq et al. (2016) L. de Clercq, R. Oswald, C. Flühmann, B. Keitch, D. Kienzler, H.-Y. Lo, M. Marinelli, D. Nadlinger, V. Negnevitsky, and J. Home, Nat. Commun. 7, 11218 (2016).
  • Pang and Jordan (2017) S. Pang and A. N. Jordan, Nat. Commun. 8, 14695 (2017).
  • Boss et al. (2017) J. M. Boss, K. S. Cujia, J. Zopes, and C. L. Degen, Science 356, 837 (2017).
  • Schmitt et al. (2017) S. Schmitt, T. Gefen, F. M. Stürner, T. Unden, G. Wolff, C. Müller, J. Scheuer, B. Naydenov, M. Markham, S. Pezzagna, et al., Science 356, 832 (2017).
  • Jordan (2017) A. N. Jordan, Science 356, 802 (2017).
  • Yang et al. (2017) J. Yang, S. Pang, and A. N. Jordan, Phys. Rev. A 96, 020301 (2017).
  • Gefen et al. (2017) T. Gefen, F. Jelezko, and A. Retzker, arXiv preprint arXiv:1702.07408 (2017).
  • Koch et al. (2007) J. Koch, T. M. Yu, J. Gambetta, A. A. Houck, D. I. Schuster, J. Majer, A. Blais, M. H. Devoret, S. M. Girvin, and R. J. Schoelkopf, Phys. Rev. A 76, 042319 (2007).
  • Paik et al. (2011) H. Paik, D. I. Schuster, L. S. Bishop, G. Kirchmair, G. Catelani, A. P. Sears, B. R. Johnson, M. J. Reagor, L. Frunzio, L. I. Glazman, et al., Phys. Rev. Lett. 107, 240501 (2011).
  • Bures (1969) D. Bures, Transactions of the American Mathematical Society 135, 199 (1969).
  • de Lange et al. (2011) G. de Lange, D. Ristè, V. V. Dobrovitski, and R. Hanson, Phys. Rev. Lett. 106, 080802 (2011).
  • Mamin et al. (2013) H. J. Mamin, M. Kim, M. H. Sherwood, C. T. Rettner, K. Ohno, D. D. Awschalom, and D. Rugar, Science 339, 557 (2013).
  • Loretz et al. (2014) M. Loretz, S. Pezzagna, J. Meijer, and C. L. Degen, Applied Physics Letters 104, 033102 (2014).
  • Sushkov et al. (2014) A. O. Sushkov, I. Lovchinsky, N. Chisholm, R. L. Walsworth, H. Park, and M. D. Lukin, Phys. Rev. Lett. 113, 197601 (2014).
  • Lovchinsky et al. (2016) I. Lovchinsky, A. O. Sushkov, E. Urbach, N. P. de Leon, S. Choi, K. De Greve, R. Evans, R. Gertner, E. Bersin, C. Müller, et al., Science 351, 836 (2016).
  • (36) Supplementary file.
  • Waldherr et al. (2012) G. Waldherr, J. Beck, P. Neumann, R. S. Said, M. Nitsche, M. L. Markham, D. J. Twitchen, J. Twamley, F. Jelezko, and J. Wrachtrup, Nature Nanotechnology 7, 105 (2012).
  • Baumgratz and Datta (2016) T. Baumgratz and A. Datta, Phys. Rev. Lett. 116, 030801 (2016).
  • Yuan and Fung (2015) H. Yuan and C.-H. F. Fung, Phys. Rev. Lett. 115, 110401 (2015).
  • Yuan (2016) H. Yuan, Phys. Rev. Lett. 117, 160801 (2016).

blank page

Supplemental Information

This document contains six sections that provide supplemental information to the data presented in the main text. Section I provides further details on the qubit sample and experimental setup. Section II presents the QFI associated with amplitude estimation discussed in the main text. Section III analyzes how the QFI scaling depends on the phase mismatch between the signal and the control. Section IV discusses an iterative procedure for improving the frequency precision and the scaling of the QFI on the measurement time. Section V provides and analysis and comparison to the technique of Rabi spectroscopy. Section VI provides statistical analysis used in the main text and supplemental figures as well as specific parameters used in each graph.

I. Experimental setup and sample parameters.

The experiment utilizes a single transmon circuit with a qubit transition frequency of GHz which is dispersively coupled to a waveguide cavity with resonance frequency GHz. The coherence properties s and s are measured with standard techniques. The time-dependent Hamiltonian is imposed via an ac Stark shift, which does not degrade the qubit coherence properties, owing to the substantial detuning of the drive.

Qubit state readout is performed by resonantly driving the cavity for ns and amplifying the transmitted microwave signal with a phase sensitive Josephson amplifier. The combined readout and state preparation fidelity of is determined by the contrast of Rabi oscillations. The measured sensitivities are not corrected for this fidelity.

The control Hamiltonian consists of ns duration rotations. All qubit drives are applied using single sideband modulation with an offset frequency of MHz with the carrier situated below the qubit transition frequency. The total effective Hamiltonian including the control is given by,

(4)

Where the control describes repeated 10-ns square pulses of amplitude MHz centered at times with giving the number of control pulses.

II. Optimal control over amplitude estimation.

As discussed in the main text, optimal control can be used to improve the QFI associated with amplitude estimation; whereas the in the uncontrolled case, the QFI associated with the amplitude does not increase in time, optimal control can saturate the bound in this case. The respective sensitivities can be determined from the eigenvalues of , which are simply . Therefore the maximum QFI without control (Eq. 3) is at most , corresponding to an amplitude sensitivity . Under optimal control the QFI can improve in time as . Supplemental Figure 1 displays the measured frequency sensitivity which is determined from the slope which is determined from a variation in . The Figure shows that both amplitude measurements are in agreement with their respective bounds.

III. Dependence of the quantum Fisher information on the phase mismatch.

To study the scaling of the QFI with time in the presence of a phase mismatch between the control and the signal we consider a measurement sequence that contains oscillatory cycles of the Hamiltonian and a phase mismatch . In this case the -pulses are not applied at the optimal times, shifting the periodic integral given by Eq. 3, leading to a QFI that scales as,

(5)

For large , the modification to the QFI is given by the first term, which for small leads to a reduction in the QFI.

IV. Iterative scaling of precision.

When we carry out the iterative improvement of Fisher information via adaptive updating of the estimated frequency in the control Hamiltonian, the total time is not typically equally distributed. Instead, the later iterations will take much longer than the earlier ones, and increase rapidly, so the last few iterations will take nearly all of the total time, as a percentage.

Suppose we make a first crude measurement, and obtain a QFI of , with a repetition of this measurement for times, so the total frequency uncertainty is bounded by

(6)

When we add control with the frequency mismatch set equal to the standard deviation of the first measurement, and chose the set the free evolution time to be , we find for our protocol the QFI for this iteration to be

(7)

This measurement (set at time ) is then itself repeated times to get a more refined estimate of the frequency. The next step is to set a longer time, , and so on. Setting the time step to be , we find

(8)

so the information scales as a double exponential with the number of iterations.

From this, we can easily see that the number of iterations needed to achieve a given duration is given when , or scales as a double logarithm of the duration . The total time is given by times the sum of all from up to the desired number of iterations. This sum over , in the exponent of the exponent has no analytic solution, so we can take two limits to bound the time. The first is that the sum is dominated by the final term (optimistic), and then we have an exact scaling,

(9)

A (very) pessimistic limit is that the total time is , which would say each measurement takes as long as the last one. This would give an approximate results for the last time in terms of the total time,

(10)

which bounds the total information as

(11)

which also yields scaling for large .

V. Rabi spectroscopy.

The optimal control for frequency estimation consists of -pulses applied every half-period of the oscillating Hamiltonian and bears resemblance to a continuous drive with a Rabi frequency of which is the basis of Rabi spectroscopy. In this section, we compare the optimal control strategy to the classic technique of Rabi spectroscopy.

We consider a resonant Rabi drive at the qubit transition frequency that produces Rabi oscillations at frequency . In the frame rotating with this drive, the time dependent Hamiltonian constitutes an additional Rabi drive at detuning . The transition probability for a qubit experiencing this Rabi drive for a time is given by,

(12)

Assuming that the detuning is small, we can ignore the prefactor. The best sensitivity is achieved if we use a detuning such that , at the side of the first fringe. The quantum fisher information can be calculated from , (QFI ()). The accumulated phase is , therefore,

(13)

The optimal detuning can be determined from the frequency that yields the side of the first fringe, . Evaluating at this optimal detuning, we have:

(14)

We see that Rabi spectroscopy yields a worse scaling for the quantum Fisher information compared to Ramsey spectroscopy.

Supplemental Figure 1: Amplitude estimation with optimal control. The amplitude sensitivity versus interaction time for the uncontrolled (red circles) and optimal control (blue triangles). Whereas the sensitivity does not improve with longer interaction time for the uncontrolled case, optimal control allows the frequency sensitivity to approach the fundamental bound .

VI. Statistical information and further analysis details.

The source of error in the frequency sensitivity presented in Figure 2e is due to the estimated standard deviation of the fit parameters in determining the slope (e.g. Fig. 2c, for which measurements are averaged for each value of , and values of are incorporated into the fit). The range of used in determining the slope is typically and this range is increased at short interaction times to where the slope is small. To measure the phase uncertainty versus number of measurements (Fig. 2d), a variable number of identical measurements () are performed to determine the mean value of , by repeating this measurement times, the variance of this phase estimation is determined. In Figure 3, the uncertainty resulting from the slope is smaller than the size of the data points.

Comments 0
Request Comment
You are adding the first comment!
How to quickly get a good reply:
  • Give credit where it’s due by listing out the positive aspects of a paper before getting into which changes should be made.
  • Be specific in your critique, and provide supporting evidence with appropriate references to substantiate general statements.
  • Your comment should inspire ideas to flow and help the author improves the paper.

The better we are at sharing our knowledge with each other, the faster we move forward.
""
The feedback must be of minimum 40 characters and the title a minimum of 5 characters
   
Add comment
Cancel
Loading ...
119805
This is a comment super asjknd jkasnjk adsnkj
Upvote
Downvote
""
The feedback must be of minumum 40 characters
The feedback must be of minumum 40 characters
Submit
Cancel

You are asking your first question!
How to quickly get a good answer:
  • Keep your question short and to the point
  • Check for grammar or spelling errors.
  • Phrase it like a question
Test
Test description